Pulsiflo

See inside your heating network from the plant room.

Pulsiflo is a diagnostic test for communal heating and heat networks. It shows which risers are starved or over-supplied, finds open bypasses and oversized pump settings, and tells you what to fix first. No one needs to enter a single home.

Developed in Liverpool. Field trials and pilots start in 2027.

Illustrative riser screen for a six-riser block A schematic of a block with six heating risers fed from one plant room. Risers 1 and 2 are marked likely over-supplied, riser 3 likely starved, riser 5 needs a spot-check, risers 4 and 6 are within range, and an open bypass is flagged in the plant room. Example only, not real data. Plant room HS Bypass open R1 ▲ 138% R2 ▲ 131% R3 ▼ 54% R4 97% R5 ? Check R6 104%
Illustrative riser screen. Percentages show estimated flow against design. Example only, not real data.

Most networks don't run as designed. Finding out why means knocking on every door.

Heating water should reach every riser and every flat in roughly its design share. In practice, bypasses are left open after flushing, valves stick, strainers clog and pumps run faster than they need to. Top-floor flats stay cold, return temperatures climb and energy is wasted.

The usual way to find these faults is an engineer with an instrument at every radiator or heat interface unit. In an occupied block of flats or a hospital that is slow, disruptive and often impossible, so problems go unfixed for years.

14,000+heat networks in the UK, serving around half a million customers.1
23–66%of generated heat lost in distribution on measured UK networks.2
68%cut in network losses on one 115-home scheme after faulty valves and bare pipework were fixed. The heat tariff halved.3
27 Jan 2026Ofgem began regulating heat networks. Existing operators must register by 26 January 2027.4

The faults Pulsiflo looks for

FaultWhat people noticeTypical fix
Open bypassHigh return temperatures, heat wasted, plant running inefficientlyClose or repair the bypass valve
Starved riser or zoneCold flats on one riser, often on upper floorsClean strainers, check isolation and balancing valves
Over-supplied riserRisers near the pump take too much water and starve the restReset balancing valves
Stuck flow-limiting valveFlow that doesn't respond to demandRepair or replace the valve
Oversized pump settingHigh pump electricity, noisy valves, low temperature differenceReduce the pump speed or curve

One visit to the plant room, not to every flat.

A Pulsiflo test uses the pump and heat source you already have. Sensors go on the outside of pipes in the plant room and communal areas, and nothing is drained or cut.

  1. Plan together

    1–2 weeks before

    We collect drawings and plant details, agree a test window and operating limits with you, and issue a risk assessment and method statement.

  2. Model the network

    1–3 days

    Your drawings and a short site survey become a model of the pipework. Anything the drawings don't tell us is flagged, not assumed.

  3. Fit the kit

    2–3 hours

    Clamp-on and strap-on sensors are fitted in the plant room and communal riser locations. No draining, no pipe cutting, no visits to homes.

  4. Run the supervised test

    1–2 hours

    Our engineer runs a short test through your existing plant, usually overnight when demand is lowest, within the limits you agreed. Everything returns to its original settings at the end.

  5. Analyse and confirm

    About a day

    Every riser and zone is screened. Where a result is uncertain, we name the two or three spot-checks that will confirm it, rather than guess.

  6. Review and report

    1–3 working days

    A qualified building services engineer checks and signs every report before you receive it.

  7. Fix and re-test

    After repairs

    Your team acts on the findings. A re-test gives you a before-and-after record of the improvement.

Timings are targets. We'll confirm them during field trials in 2027.

A report your maintenance team can act on.

Findings are ranked by energy, cost and comfort impact, each with the evidence behind it and a named fix.

Riser and zone screen

Each riser marked within range, likely starved, likely over-supplied or needing a check, with a stated level of confidence.

Ranked fault list

Location, likely cause, recommended fix and priority for every fault found.

Settings to apply

Recommended pump settings and balancing priorities your engineers can put in place straight away.

Savings estimates

Expected energy, cost and carbon savings for each action, so you can fund the fixes that pay back first.

Targeted spot-checks

The few confirming measurements worth taking, in place of a building-wide survey.

Evidence pack

A signed before-and-after record to support Ofgem reporting and performance improvement plans.

Ongoing monitoring

Planned: Pulsiflo Monitor will watch for new faults between tests and alert you before residents notice.

Extract from an example report

FindingLocationRecommended actionPriority
Bypass openPlant room, header bypassClose or repair the bypass valveHigh
Riser likely starvedRiser 3Clean strainer, check isolation valveHigh
Pump over-speedMain circulating pumpReduce pump settingMedium
Risers likely over-suppliedRisers 1 and 2Apply recommended balancing settingsMedium
Result uncertainRiser 5One clamp-on spot-check readingCheck

Illustrative example matching the schematic above. Not from a real building.

How it compares with a balancing survey.

Pulsiflo tells you where to focus. Your balancing engineers still do the fixing, with far less time spent finding the problem.

Conventional balancing surveyPulsiflo test
Access neededEvery flat, ward or officePlant room and communal areas only
Site time, 100-home blockSeveral engineer-days, plus repeat visits where access failsAbout half a day, plus a few targeted spot-checks
Finds bypasses, starved risers and pump over-speedOnly where an engineer happens to lookYes, screened across the whole network
States its confidenceNoYes, with uncertain results marked for checking
Measures every individual radiatorYesNo, results are at riser and zone level
Hardware left behindNoneNone after a test

We report only what the measurements support. Results are given for risers and zones, not individual radiators. Where we aren't confident, the report says so and names the check that will settle it.

Built around the safety of residents and plant.

Every site starts with read-only logging. An active test follows only once the site has been checked and you have signed off the limits.

  • Limits you agreeWritten into the method statement and loaded as a signed configuration before any test.
  • Automatic stopThe test aborts on any plant alarm or lost signal and restores normal operation.
  • Settings restoredOriginal settings return at the end of every test, and normal running is confirmed before we leave.
  • Physical stop button and watchdogA hardware failsafe returns the plant to its original state if anything goes wrong.
  • Plant safety devices untouchedPulsiflo never overrides boiler, heat pump or pump protection.
  • Engineer on site throughoutTests run in a scheduled window with your competent person present, and avoid the coldest weeks.
  • Hot water protectedDomestic hot water and legionella set-points are never reduced.
  • Independent reviewOur safety case is reviewed by an independent chartered engineer before any live test.

Who Pulsiflo is for.

Heat network operators

Evidence that your networks perform, ready for Ofgem registration and the technical standards to follow, without entering every home.

Housing associations and councils

Find out why flats are cold and target repairs, instead of commissioning building-wide surveys. Supports your duties on damp, mould and excess cold.

Consultancies, commissioning and FM firms

A measurement service, and later a licensed tool, that cuts days of site time and proves your results to clients.

NHS and public estates from 2028

Diagnosis from the plant room with minimal disruption to wards and clinical areas.

Why it matters now.

Regulation

Ofgem has regulated heat networks since January 2026, and a Heat Network Technical Assurance Scheme is planned to set minimum performance standards. Operators will need evidence.

Heat pumps

Heat pumps and condensing boilers need low return temperatures. A hidden open bypass costs more under a heat pump than it did under a gas boiler.

Warm, healthy homes

Awaab's Law extends social landlords' duties to hazards including excess cold from 30 November 2026.5

Energy costs

Lost heat and wasted pump electricity are paid for by residents through their bills. Finding the faults is the first step to lower tariffs.

Your data stays protected, and in the UK.

  • UK-hostedCloud hosting in a UK region, with encryption in transit and at rest.
  • Controlled accessRole-based permissions and audit logs on every test, review and report.
  • UK GDPRA data protection impact assessment before every pilot, and a data processing agreement with each customer.
  • Accountable resultsEvery report has a named signatory and can be traced to the data and model version behind it.

Built by people who have done the job.

Pulsiflo was founded in Liverpool in 2026 by a building services engineer and a software and AI engineer.

One has carried out water and air balancing across a live hospital estate and knows at first hand how slow terminal-by-terminal testing is in occupied buildings. The other has spent more than a decade delivering software for government and enterprise clients, with postgraduate research in machine learning.

Together they cover the hydronics, the analysis, the safety case and the site work that a trustworthy diagnostic needs.

Questions we're often asked.

Do you need access to flats or wards?

No. Everything is fitted in the plant room and communal areas such as riser cupboards. Any confirming spot-checks are taken on accessible communal pipework.

Will residents notice the test?

The test is short, runs when demand is lowest and stays within limits you agree. Hot water set-points are never reduced, and all settings are restored at the end.

Does it replace balancing or heat meters?

No. Pulsiflo shows where the problems are so your engineers can fix the right valves first. It works on networks that don't have full metering, and where meters are installed it can use their data too.

What kind of networks does it suit?

Our first focus is communal heating and heat networks with several risers and a pump that has a speed input. Hospitals, campuses and chilled-water systems will follow.

How accurate is it?

We are measuring that in field trials during 2027 against independent readings, and we'll publish the results. Every finding comes with a stated confidence, and uncertain ones are marked for confirmation.

How does the method work?

We share technical details of the method with pilot partners under a confidentiality agreement. Get in touch if you'd like a briefing.

Can I buy a test now?

Not yet. We're preparing for field trials and early pilots in 2027 and are talking to organisations who'd like to take part.

Host a pilot in 2027.

We're looking for heat network operators, housing providers and commissioning firms to host field trials and early pilots. If you have a network with comfort, cost or compliance problems, we'd like to hear from you.